Victron (Charger) Ladegerät 24/25 – 24 V, 25 A (PCH024025001)

Victron Energy · battery_charger

Technische Daten (aus Herstellerdokumenten)

FeldWertBedingungQuelle
acConnectionTerminalType Screw terminals 4 mm² (11 AWG) - victron_api_2026_11
acInputFrequencyRange [45, 65] Hz - victron_api_2026_11
aCInputVoltageBucket 120 V - 240 V - victron_api_2026_11
aCInputVoltageRange [90, 265] V - victron_api_2026_11
batteryCapacityRange [100, 400] Ah - victron_api_2026_11
batteryConnectionTerminalType M6 bolts - victron_api_2026_11
batteryVoltageNominal 24 V - victron_api_2026_11
canBeUsedAsPowerSupply ja - victron_api_2026_11
chargeAlgorithm Adaptive, 4-stage - victron_api_2026_11
chargeCurrentNominal 25 A - victron_api_2026_11
chargeCurrentStarter 4 A - victron_api_2026_11
chargeVoltageAbsorption 28.8 V - victron_api_2026_11
chargeVoltageFloat 27.6 V - victron_api_2026_11
chargeVoltageStorage 26.4 V - victron_api_2026_11
dCInputVoltageRange [90, 400] V Batteriespannung am DC-Eingang, nicht die PV-Spannung victron_api_2026_11
depth 108 mm - victron_api_2026_11
forcedCooling ja - victron_api_2026_11
height 350 mm - victron_api_2026_11
maxHumidity 95 % - victron_api_2026_11
max_charge_current 25 A aus Victron-Feld chargeCurrentNominal victron_api_2026_11
operatingTemperatureRange [-20, 60] °C - victron_api_2026_11
powerFactor 1 - victron_api_2026_11
Programable Settings can be change via a data port. RJ45 UTP cable and MK2-USB interface are required (not included) - victron_api_2026_11
protectionCategory IP21 - victron_api_2026_11
protections Output short-circuit,High battery voltage,Over temperature,Battery reverse polarity - victron_api_2026_11
temperatureSensor Included - victron_api_2026_11
vibration IEC68-2-6:10-150Hz/1.0G - victron_api_2026_11
weight 3.8 kg - victron_api_2026_11
width 200 mm - victron_api_2026_11
Frage zur Victron (Charger) Ladegerät 24/25 – 24 V, 25 A (PCH024025001) stellen