Technische Daten (aus Herstellerdokumenten)
| Feld | Wert | Bedingung | Quelle |
|---|---|---|---|
| connectProfiles | See our website | - | victron_api_2026_11 |
| continuousCurrent1224 | 230 A | - | victron_api_2026_11 |
| continuousCurrent48 | 80 A | - | victron_api_2026_11 |
| controlCableIncluded | ja | - | victron_api_2026_11 |
| controlInput | The Cyrix engages when the control input is high (appr. Battery voltage) The Cyrix disengages when the control input is left free floating or pulled low | - | victron_api_2026_11 |
| currentConsumptionOpen | 4 mA | - | victron_api_2026_11 |
| depth | 50 mm | - | victron_api_2026_11 |
| height | 65 mm | - | victron_api_2026_11 |
| ledStatusIndication | ja | - | victron_api_2026_11 |
| nominalBatteryVoltage | 24V or 48V (automatic detection) | - | victron_api_2026_11 |
| protectionCategory | IP54 | - | victron_api_2026_11 |
| weight | 0.27 kg | - | victron_api_2026_11 |
| width | 100 mm | - | victron_api_2026_11 |