Technische Daten (aus Herstellerdokumenten)
| Feld | Wert | Bedingung | Quelle |
|---|---|---|---|
| allowChargreCurrentRating | 0.5A at 60VDC, protected by resettable fuse | - | victron_api_2026_11 |
| allowDischargreCurrentRating1 | 0.5A at 60VDC, protected by resettable fuse | - | victron_api_2026_11 |
| auxCurrentRating | 1.1 A continuous, protected by resettable fuse | - | victron_api_2026_11 |
| batteryCommunicationTerminals | Terminals with M8 circular connectors | - | victron_api_2026_11 |
| busbarConnections | M8 | - | victron_api_2026_11 |
| busbarDimensions | 8mm x 30mm | - | victron_api_2026_11 |
| busbarMaterial | Tinned copper | - | victron_api_2026_11 |
| currentRating | 500 A | - | victron_api_2026_11 |
| currentRatingpeak | 600 A | - | victron_api_2026_11 |
| depth | 80 mm | - | victron_api_2026_11 |
| ems | EN-IEC 61000-6-3 | - | victron_api_2026_11 |
| height | 190 mm | - | victron_api_2026_11 |
| ioConnection | Removable multi-connector with screw terminals | - | victron_api_2026_11 |
| lynxDistributorFuseMonitoring | RJ10 (RJ10 cables ship with each Lynx Distributor) | - | victron_api_2026_11 |
| maxHumidity | 95 % | - | victron_api_2026_11 |
| maxInputVoltage | 75 V | - | victron_api_2026_11 |
| operatingTempRange | [-40, 60] °C | - | victron_api_2026_11 |
| powerConsumptionOff | 0.3mA for all system voltages | - | victron_api_2026_11 |
| powerConsumptionOn | Approximately 2.6W (217mA at 12V) depending on the state of the relays | - | victron_api_2026_11 |
| powerConsumptionStandby | Approximately 0.6W (50mA at 12V) | - | victron_api_2026_11 |
| prechargeLoadResistance | 10Ω and above for 12V systems 20Ω and above for 24V and 48V systems | - | victron_api_2026_11 |
| programmableRelay | SPDT - 2 A at 60 VDC | - | victron_api_2026_11 |
| protectionCategory | IP22 | - | victron_api_2026_11 |
| qms | NEN-EN-ISO 9001 | - | victron_api_2026_11 |
| reversePolarityProtection | No | - | victron_api_2026_11 |
| storageTempRange | [-40, 60] °C | - | victron_api_2026_11 |
| systemVoltages | 12V or 24V or 48V | - | victron_api_2026_11 |
| veCan | RJ45 (Two RJ45 terminators included) | - | victron_api_2026_11 |
| voltageRange | [9, 60] V | - | victron_api_2026_11 |
| weight | 1.9 kg | - | victron_api_2026_11 |
| width | 180 mm | - | victron_api_2026_11 |
Gerätebeziehungen
Smart Lithium 12,8/100 (Baureihe, Praxis- und Kombinationswissen)
(Victron Energy)
Typ: kompatibel · Schnittstelle: BMS-Kabel M8 · Status: freigegeben
Einschränkung: Nur Victron Lithium Battery Smart (für Lithium NG die NG-Version)
Einschränkung: Nur Victron Lithium Battery Smart (für Lithium NG die NG-Version)
Smart Lithium 12,8/200 (Baureihe, Praxis- und Kombinationswissen)
(Victron Energy)
Typ: kompatibel · Schnittstelle: BMS-Kabel M8 · Status: freigegeben
Einschränkung: Nur Victron Lithium Battery Smart (für Lithium NG die NG-Version)
Einschränkung: Nur Victron Lithium Battery Smart (für Lithium NG die NG-Version)
Cerbo GX (Baureihe, Praxis- und Kombinationswissen)
(Victron Energy)
Typ: kommunikation · Schnittstelle: VE.Can · Status: freigegeben
Victron Lynx Distributor – 1,000 A (LYN060102000)
(Victron Energy)
Typ: kompatibel · Schnittstelle: Lynx-Stromschiene (M10) · Status: freigegeben
Victron Lynx Distributor – 1,000 A (LYN060102010)
(Victron Energy)
Typ: kompatibel · Schnittstelle: Lynx-Stromschiene (M10) · Status: freigegeben