| allowChargreCurrentRating |
0.5A at 60VDC, protected by resettable fuse |
- |
victron_api_2026_11 |
| allowDischargreCurrentRating1 |
0.5A at 60VDC, protected by resettable fuse |
- |
victron_api_2026_11 |
| auxCurrentRating |
1.1 A continuous, protected by resettable fuse |
- |
victron_api_2026_11 |
| batteryCommunicationTerminals |
Terminals with M8 circular connectors |
- |
victron_api_2026_11 |
| busbarConnections |
M10 |
- |
victron_api_2026_11 |
| busbarDimensions |
8mm x 30mm |
- |
victron_api_2026_11 |
| busbarMaterial |
Tinned copper |
- |
victron_api_2026_11 |
| currentRating |
1,000 A |
- |
victron_api_2026_11 |
| currentRatingpeak |
1,200 A |
- |
victron_api_2026_11 |
| depth |
100 mm |
- |
victron_api_2026_11 |
| ems |
EN-IEC 61000-6-3 |
- |
victron_api_2026_11 |
| height |
230 mm |
- |
victron_api_2026_11 |
| lynxDistributorFuseMonitoring |
RJ10 (RJ10 cables ship with each Lynx Distributor) |
- |
victron_api_2026_11 |
| maxHumidity |
95 % |
- |
victron_api_2026_11 |
| maxInputVoltage |
75 V |
- |
victron_api_2026_11 |
| operatingTempRange |
[-40, 60] °C |
- |
victron_api_2026_11 |
| powerConsumptionOff |
0.3mA for all system voltages |
- |
victron_api_2026_11 |
| powerConsumptionOn |
Approximately 4.2W (350mA at 12V) depending on the state of the relays |
- |
victron_api_2026_11 |
| powerConsumptionStandby |
Approximately 0.6W (50mA at 12V) |
- |
victron_api_2026_11 |
| prechargeLoadResistance |
10Ω and above for 12V systems 20Ω and above for 24V and 48V systems |
- |
victron_api_2026_11 |
| programmableRelay |
SPDT - 2 A at 60 VDC |
- |
victron_api_2026_11 |
| protectionCategory |
IP22 |
- |
victron_api_2026_11 |
| qms |
NEN-EN-ISO 9001 |
- |
victron_api_2026_11 |
| storageTempRange |
[-40, 60] °C |
- |
victron_api_2026_11 |
| systemVoltages |
12V or 24V or 48V |
- |
victron_api_2026_11 |
| veCan |
RJ45 |
- |
victron_api_2026_11 |
| voltageRange |
[9, 60] V |
- |
victron_api_2026_11 |
| weight |
2.7 kg |
- |
victron_api_2026_11 |
| width |
180 mm |
- |
victron_api_2026_11 |