Technische Daten (aus Herstellerdokumenten)
| Feld | Wert | Bedingung | Quelle |
|---|---|---|---|
| continuousOutputCurrent | 20 A | - | victron_api_2026_11 |
| dcConnectionTerminalType | Two 1.8m input and output cables 2.6 mm² (13 AWG) | - | victron_api_2026_11 |
| dcOutputVoltageBucket | 12 V | - | victron_api_2026_11 |
| depth | 32 mm | - | victron_api_2026_11 |
| height | 74 mm | - | victron_api_2026_11 |
| inputVoltageBucket | 24 V | - | victron_api_2026_11 |
| inputVoltageRange | [15, 40] V | - | victron_api_2026_11 |
| maxEfficiency | 95 | - | victron_api_2026_11 |
| max_charge_current | 20 A | aus Victron-Feld continuousOutputCurrent | victron_api_2026_11 |
| noLoadCurrentConsumption | 50 mA | - | victron_api_2026_11 |
| operatingTempRange | [-40, 70] °C | - | victron_api_2026_11 |
| outputDeratingAbove40 | 3 % | - | victron_api_2026_11 |
| outputVoltage | 12 V | - | victron_api_2026_11 |
| outputVoltageTolerance | 3 % | - | victron_api_2026_11 |
| protectionCategory | IP67 | - | victron_api_2026_11 |
| protections | Short-circuit proof,Overload,Reverse polarity (fuse),Over temperature | - | victron_api_2026_11 |
| rippleAndNoise | 0.075 Vmpp | - | victron_api_2026_11 |
| underVoltageRestart | 14 V | - | victron_api_2026_11 |
| underVoltageShutdown | 13 V | - | victron_api_2026_11 |
| vibration | IEC68-2-6:10-150Hz/1.0G | - | victron_api_2026_11 |
| weight | 0.3 kg | - | victron_api_2026_11 |
| width | 74 mm | - | victron_api_2026_11 |