Victron Quattro 24/3000/70 – 24 V, 3,000 VA, 2,400 W (QUA243020010)

Victron Energy · inverter_charger

Technische Daten (aus Herstellerdokumenten)

FeldWertBedingungQuelle
aCConnectionTerminalType Screw terminals 13 mm² (6 AWG) - victron_api_2026_11
aCInputFrequencyRange [50, 60] Hz - victron_api_2026_11
aCInputVoltageRange [187, 250] V - victron_api_2026_11
aCOutputFrequency 50 Hz - victron_api_2026_11
aCOutputVoltage 230 VAC - victron_api_2026_11
antiIslandingStandard See our website - victron_api_2026_11
AuxiliaryOutput ja - victron_api_2026_11
batteryConnectionTerminalType M8 bolts (two for positive and two for negative connection) - victron_api_2026_11
batteryVoltageNominal 24 V - victron_api_2026_11
chargeAlgorithm Adaptive, 4-stage - victron_api_2026_11
chargeVoltageAbsorption 28.8 VDC - victron_api_2026_11
chargeVoltageFloat 27.6 VDC - victron_api_2026_11
chargeVoltageStorage 26.4 VDC - victron_api_2026_11
communicationPort VE.Bus - victron_api_2026_11
communicationPortGeneral ja - victron_api_2026_11
continuous_output_power 2400 W aus Victron-Feld contPowerW25 (bei 25 °C) victron_api_2026_11
contPowerVA25 3,000 VA - victron_api_2026_11
contPowerW25 2,400 W - victron_api_2026_11
contPowerW40 2,200 W - victron_api_2026_11
contPowerW65 1,700 W - victron_api_2026_11
dCInputCurrent 125 A - victron_api_2026_11
dCInputVoltageRange [19, 33] VDC Batteriespannung am DC-Eingang, nicht die PV-Spannung victron_api_2026_11
depth 218 mm - victron_api_2026_11
fanAssistCooling ja - victron_api_2026_11
height 362 mm - victron_api_2026_11
icw 10,000 A - victron_api_2026_11
integratedTransferSwitch ja - victron_api_2026_11
maxAltitude 2,000 m - victron_api_2026_11
maxEfficiency 94 % - victron_api_2026_11
maxFeedTroughCurrent 2x 100A - victron_api_2026_11
maxHumidity 95 % - victron_api_2026_11
maximumBatteryChargeCurrent 70 A - victron_api_2026_11
MaxOutputAcCurrent 11 A - victron_api_2026_11
MaxOutputAcCurrentFault 32 A - victron_api_2026_11
max_charge_current 70 A aus Victron-Feld maximumBatteryChargeCurrent victron_api_2026_11
numberAcInputs 2 - victron_api_2026_11
operatingTempRange [-20, 60] °C - victron_api_2026_11
ovciiiIcw ja - victron_api_2026_11
parallelOperation ja - victron_api_2026_11
peakPowerRating 6,000 W - victron_api_2026_11
pollutionDegree 2 - victron_api_2026_11
powerAssist ja - victron_api_2026_11
powerControl ja - victron_api_2026_11
programmableRelay AC rating: 230V / 4A, DC rating: 4A up to 35VDC and 1A up to 60VDC - victron_api_2026_11
protectionCategory IP20 - victron_api_2026_11
protections Output short-circuit,Overload,High battery voltage,Low battery voltage,Over temperature,AC voltage on inverter output,Excessive DC ripple - victron_api_2026_11
relayTerminal Screw terminal 3-pole - victron_api_2026_11
remoteTerminal On / Off / Charger only - victron_api_2026_11
remoteTerminalType Screw terminal two pole - victron_api_2026_11
starterBatteryChargeCurrent 4 A - victron_api_2026_11
temperatureSensor Included - victron_api_2026_11
threePhaseOperation ja - victron_api_2026_11
vebusTerminalType Two RJ45 terminals - victron_api_2026_11
weight 19 kg - victron_api_2026_11
width 258 mm - victron_api_2026_11
zeroLoadPower 20 W - victron_api_2026_11
zeroLoadPowerAES 15 W - victron_api_2026_11
zeroLoadPowerSearch 10 W - victron_api_2026_11

Gerätebeziehungen

Cerbo GX (Baureihe, Praxis- und Kombinationswissen) (Victron Energy)
Typ: kommunikation · Schnittstelle: VE.Bus (RJ45, Standard-UTP-Kabel) · Status: freigegeben
Einschränkung: Nur ein VE.Bus-System pro GX-Gerät; freie VE.Bus-Buchsen offen lassen
Frage zur Victron Quattro 24/3000/70 – 24 V, 3,000 VA, 2,400 W (QUA243020010) stellen