Victron Skylla-TG GMDSS 24/30 – 24 V, 30 A (SDTG2400302)

Victron Energy · battery_charger

Technische Daten (aus Herstellerdokumenten)

FeldWertBedingungQuelle
acConnection Three wire 2,5 mm² (AWG 6) cable Length: 2 m - victron_api_2026_11
acInputFrequencyRange [45, 65] Hz - victron_api_2026_11
aCInputVoltage 120V or 230V - victron_api_2026_11
aCInputVoltageBucket 120 V - 240 V - victron_api_2026_11
aCInputVoltageRange [90, 265] V - victron_api_2026_11
batteryConnection Red and black 1.5 meter cable - victron_api_2026_11
batteryVoltageNominal 24 V - victron_api_2026_11
canBeUsedAsPowerSupply ja - victron_api_2026_11
chargeAlgorithm IUoU, three stage charging - victron_api_2026_11
chargeCurrentMain110 22 A - victron_api_2026_11
chargeCurrentNominal 30 A - victron_api_2026_11
chargeVoltageAbsorption 38.5 V - victron_api_2026_11
chargeVoltageFloat 26.5 V - victron_api_2026_11
depth 147 mm - victron_api_2026_11
forcedCooling ja - victron_api_2026_11
gmdssConnection One 1,5 m cable (+ to be taken directly from the battery) - victron_api_2026_11
height 485 mm - victron_api_2026_11
maritime IEC 60945 - victron_api_2026_11
maxHumidity 95 % - victron_api_2026_11
max_charge_current 30 A aus Victron-Feld chargeCurrentNominal victron_api_2026_11
operatingTemperatureRange [-40, 50] °C - victron_api_2026_11
powerFactor 1 - victron_api_2026_11
Programable Settings can be changed via DIP switches and potentiometers - victron_api_2026_11
protectionCategory IP21 - victron_api_2026_11
protections Output short-circuit,High battery voltage,Over temperature,Battery reverse polarity - victron_api_2026_11
temperatureSensor Included - victron_api_2026_11
weight 6 kg - victron_api_2026_11
width 250 mm - victron_api_2026_11
Frage zur Victron Skylla-TG GMDSS 24/30 – 24 V, 30 A (SDTG2400302) stellen