| alarmOutputDelay |
12 s |
- |
victron_api_2026_11 |
| alarmTerminal |
Screw terminal 3-pole |
- |
victron_api_2026_11 |
| batteryAndLoadTerminals |
M6 bolts |
- |
victron_api_2026_11 |
| batteryVoltageNominal |
12V or 24V (automatic detection) |
- |
victron_api_2026_11 |
| bluetooth |
Yes |
- |
victron_api_2026_11 |
| currentConsumptionWhenOffB |
0.9 mA |
- |
victron_api_2026_11 |
| currentConsumptionWhenOffBO |
0.7 mA |
- |
victron_api_2026_11 |
| currentConsumptionWhenOnB |
1.4 mA |
- |
victron_api_2026_11 |
| currentConsumptionWhenOnBO |
1.2 mA |
- |
victron_api_2026_11 |
| defaultThresholdDisengage12 |
10.5 V |
- |
victron_api_2026_11 |
| defaultThresholdDisengage24 |
21 V |
- |
victron_api_2026_11 |
| defaultThresholdEngage12 |
12 V |
- |
victron_api_2026_11 |
| defaultThresholdEngage24 |
24 V |
- |
victron_api_2026_11 |
| depth |
106 mm |
- |
victron_api_2026_11 |
| height |
48 mm |
- |
victron_api_2026_11 |
| loadDisconnectDelay |
90 s |
- |
victron_api_2026_11 |
| loadReconnectDelay |
30 s |
- |
victron_api_2026_11 |
| maximumContinuousLoadCurrentRating40 |
65 A |
- |
victron_api_2026_11 |
| maximumContinuousLoadCurrentRating60 |
39 A |
- |
victron_api_2026_11 |
| maximumLoadAlarmOutput |
50 mA |
- |
victron_api_2026_11 |
| operatingTemperatureRange |
[-40, 50] °C |
- |
victron_api_2026_11 |
| operatingVoltageRange |
[6, 35] V |
- |
victron_api_2026_11 |
| peakCurrentRating |
250 A |
- |
victron_api_2026_11 |
| protectionCategoryConnectionArea |
IP00 |
- |
victron_api_2026_11 |
| protectionCategoryElectronicComponents |
IP67 |
- |
victron_api_2026_11 |
| protections |
Output short-circuit |
- |
victron_api_2026_11 |
| remoteOnOffTerminal |
ja |
- |
victron_api_2026_11 |
| remoteTerminal |
Screw terminal two pole |
- |
victron_api_2026_11 |
| reverseCurrent |
No |
- |
victron_api_2026_11 |
| weight |
0.2 kg |
- |
victron_api_2026_11 |
| width |
55 mm |
- |
victron_api_2026_11 |