Technische Daten (aus Herstellerdokumenten)
| Feld | Wert | Bedingung | Quelle |
|---|---|---|---|
| adjustableChargeVoltageRange | [36, 60] V | - | victron_api_2026_11 |
| batteryConnectionTerminalType | M8 bolts (two for positive and two for negative connection) | - | victron_api_2026_11 |
| batteryVoltageAutoSelect | 48V | - | victron_api_2026_11 |
| bluetooth | ja | - | victron_api_2026_11 |
| bluetoothFrequencyRange | [2,402, 2,480] Hz | - | victron_api_2026_11 |
| bluetoothPower | 4 dBmW | - | victron_api_2026_11 |
| chargeAlgorithm | Multi-stage adaptive (adjustable) | - | victron_api_2026_11 |
| chargeVoltageAbsorption | 57.6V (adjustable) | - | victron_api_2026_11 |
| chargeVoltageFloat | 55.2V (adjustable) | - | victron_api_2026_11 |
| dataCommunication | VE.Direct,VE.Can,Bluetooth | - | victron_api_2026_11 |
| dataRetentionPeriod | 30 d | - | victron_api_2026_11 |
| depth | 146 mm | - | victron_api_2026_11 |
| height | 487 mm | - | victron_api_2026_11 |
| maxDCOutputChargingPowerPerTracker | 4,000 | - | victron_api_2026_11 |
| maxDCOutputChargingPowerTrackersCombined | 11,520 W | - | victron_api_2026_11 |
| maxEfficiency | 96 % | - | victron_api_2026_11 |
| maxHumidity | 95 % | - | victron_api_2026_11 |
| maximumChargePower | 11.5 kW | - | victron_api_2026_11 |
| maxPVArrayPerTracker | 7,200 W | - | victron_api_2026_11 |
| maxPVDCVoltage | 450 V | - | victron_api_2026_11 |
| maxPVOperationalInputCurrentTracker | 16 | - | victron_api_2026_11 |
| maxPVShortCircuitCurrent | 20 A | - | victron_api_2026_11 |
| max_charge_current | 200 A | aus Victron-Feld ratedChargeCurrent | victron_api_2026_11 |
| mPPTOperatingVoltageRange | [65, 450] V | - | victron_api_2026_11 |
| numberOfGeneralPurposeAnalogue | 2 | - | victron_api_2026_11 |
| numberOfSyncParallelOperatingUnits | 25 | - | victron_api_2026_11 |
| numberOfTrackers | 4 | - | victron_api_2026_11 |
| operatingTempRange | [-40, 60] °C | - | victron_api_2026_11 |
| programmableRelay | DC rating: 4A up to 35VDC and 1A up to 70VDC | - | victron_api_2026_11 |
| protectionCategory | IP21 | - | victron_api_2026_11 |
| protections | PV reverse polarity,Output short-circuit,Over temperature | - | victron_api_2026_11 |
| pVConnectionTerminalType | MC4 male/female pair per tracker | - | victron_api_2026_11 |
| pVIsolationFailLevel | 100 kΩ | - | victron_api_2026_11 |
| ratedChargeCurrent | 200 A | - | victron_api_2026_11 |
| remoteOnOffTerminal | ja | - | victron_api_2026_11 |
| selfConsumption | 15mA | - | victron_api_2026_11 |
| startUpPVDCVoltage | 120V | - | victron_api_2026_11 |
| temperatureSensor | Included | - | victron_api_2026_11 |
| weight | 13.7 kg | - | victron_api_2026_11 |
| width | 434 mm | - | victron_api_2026_11 |
Gerätebeziehungen
Cerbo GX (Baureihe, Praxis- und Kombinationswissen)
(Victron Energy)
Typ: kommunikation · Schnittstelle: VE.Can · Status: freigegeben
Einschränkung: Für MPPT RS: Anbindung über VE.Direct oder VE.Can möglich
Einschränkung: Für MPPT RS: Anbindung über VE.Direct oder VE.Can möglich