Technische Daten (aus Herstellerdokumenten)
| Feld | Wert | Bedingung | Quelle |
|---|---|---|---|
| acInputVoltage | 120 VAC | - | victron_api_2026_11 |
| acOutputVoltage | 240 VAC | - | victron_api_2026_11 |
| connectionTerminalType | Screw terminals 35 mm² (2 AWG) | - | victron_api_2026_11 |
| depth | 110 mm | - | victron_api_2026_11 |
| frequency | [50, 60] Hz | - | victron_api_2026_11 |
| height | 425 mm | - | victron_api_2026_11 |
| inputCircuitBreaker | 100A, Two Pole | - | victron_api_2026_11 |
| maxACFeedCurrent240VAC | 100 A | - | victron_api_2026_11 |
| neutralCurrent30m | 32 A | - | victron_api_2026_11 |
| neutralCurrentCont | 28 A | - | victron_api_2026_11 |
| neutralPowerRating30m | 3,800 VA | - | victron_api_2026_11 |
| protectionCategory | IP21 | - | victron_api_2026_11 |
| transformerType | Toroidal | - | victron_api_2026_11 |
| weight | 13.5 kg | - | victron_api_2026_11 |
| width | 214 mm | - | victron_api_2026_11 |