| acConnection |
Screw terminals 10 mm² (8 AWG) |
- |
victron_api_2026_11 |
| aCOutputVoltage |
230 V |
- |
victron_api_2026_11 |
| batteryConnection |
M8 bolts |
- |
victron_api_2026_11 |
| batteryTemperatureSensor |
Included |
- |
victron_api_2026_11 |
| batteryVoltageNominal |
48 V |
- |
victron_api_2026_11 |
| batteryVoltageSense |
ja |
- |
victron_api_2026_11 |
| bluetooth |
Yes, -4dBm, 2402 – 2480 MHz |
- |
victron_api_2026_11 |
| chargeVoltageAbsorption |
57.6 V |
- |
victron_api_2026_11 |
| chargeVoltageFloat |
55.2 V |
- |
victron_api_2026_11 |
| chargeVoltageRange |
[36, 60] V |
- |
victron_api_2026_11 |
| communicationPort |
Bluetooth,VE.Direct,VE.Can |
- |
victron_api_2026_11 |
| continuous_output_power |
4500 W |
aus Victron-Feld contPowerW40 (bei 40 °C) |
victron_api_2026_11 |
| contPowerW25a |
4,800 W |
- |
victron_api_2026_11 |
| contPowerW25b |
5,300 W |
- |
victron_api_2026_11 |
| contPowerW40 |
4,500 W |
- |
victron_api_2026_11 |
| contPowerW65 |
3,000 W |
- |
victron_api_2026_11 |
| Cooling |
ja |
- |
victron_api_2026_11 |
| dCInputVoltageRange |
[38, 62] V |
Batteriespannung am DC-Eingang, nicht die PV-Spannung |
victron_api_2026_11 |
| depth |
125 mm |
- |
victron_api_2026_11 |
| earthLeakageTripLevel |
30 mA |
- |
victron_api_2026_11 |
| frequency |
50 Hz |
- |
victron_api_2026_11 |
| fullyProgramable |
ja |
- |
victron_api_2026_11 |
| generalPurposePort |
Yes, 2x |
- |
victron_api_2026_11 |
| height |
425 mm |
- |
victron_api_2026_11 |
| includesMPPT |
ja |
- |
victron_api_2026_11 |
| isolationFailLevel |
100 kΩ |
- |
victron_api_2026_11 |
| lowBatteryRestart |
43.6 V |
- |
victron_api_2026_11 |
| lowBatteryShutdown |
37.2 V |
- |
victron_api_2026_11 |
| maxAcCoupledSolar |
5,000 W |
- |
victron_api_2026_11 |
| maxAltitude |
2,000 m |
- |
victron_api_2026_11 |
| maxChargeCurrent |
100 A |
- |
victron_api_2026_11 |
| MaxDcVoltage |
450 V |
- |
victron_api_2026_11 |
| maxEfficiency |
96.5 % |
- |
victron_api_2026_11 |
| maxHumidity |
95 % |
- |
victron_api_2026_11 |
| MaximumContInvCurrent |
25 A |
- |
victron_api_2026_11 |
| maxPvOperationalCurrent |
18 A |
- |
victron_api_2026_11 |
| maxPVShortCircuitCurrent |
30 A |
- |
victron_api_2026_11 |
| maxPVShortCircuitCurrentRevPol |
20 A |
- |
victron_api_2026_11 |
| maxSolarChargePower |
4,000 W |
- |
victron_api_2026_11 |
| mpptOperatingVoltageRange |
[65, 450] V |
- |
victron_api_2026_11 |
| NomDcVoltage |
300 V |
- |
victron_api_2026_11 |
| operatingTempRange |
[-40, 65] °C |
- |
victron_api_2026_11 |
| parallel3phase |
12 parallel units supported, 3 phase supports 4 units per phase |
- |
victron_api_2026_11 |
| peakPowerRating3s |
9,000 W |
- |
victron_api_2026_11 |
| peakPowerRating4m |
7,000 W |
- |
victron_api_2026_11 |
| programmableRelay |
DC rating: 4A up to 35VDC and 1A up to 70VDC |
- |
victron_api_2026_11 |
| protectionCategory |
IP21 |
- |
victron_api_2026_11 |
| protections |
Output short-circuit,Overload,High battery voltage,Low battery voltage,Over temperature,AC voltage on inverter output,Solar earth leakage |
- |
victron_api_2026_11 |
| remoteOnOff |
ja |
- |
victron_api_2026_11 |
| ShortCircuitCurrent |
45 A |
- |
victron_api_2026_11 |
| startupVoltage |
120 V |
- |
victron_api_2026_11 |
| weight |
11 kg |
- |
victron_api_2026_11 |
| width |
440 mm |
- |
victron_api_2026_11 |
| zeroLoadPower |
20 W |
- |
victron_api_2026_11 |